General User

chevron-rightWearing a Taghashtag

The tag, with hook & loop elastic armband is designed to be placed around the wearer's upper arm.

Fix and tighten according to comfort without restricting blood-flow.

chevron-rightTurning on / off & checking batteryhashtag

To turn a Tag on, hold down the button for 5 second until you hear 2 ascending tones - release button

To turn a Tag off, hold down the button for 5 second until you hear 2 descending tones - release button

On request, Tags can be configured by Zonr to be always on, preventing users from turning them off.

To find out whether a Tag has a low battery, press the button:

*Single beep = low

*2 beeps = medium

*3 beeps = high/full

chevron-rightSafe Mode - Info for Tag Wearershashtag

Safe Mode temporarily disables all alerting. A helpful function for 'bucket down' scenarios.

No action needs to be taken by Tag wearers when Safe Mode is enabled. The Plant Operator is in charge of enabling and disabling Safe Mode.

chevron-rightEntering an exclusion Zone - approved incursionshashtag

There may be instances when a person wearing a Tag needs to enter the exclusion zone. To bypass the Zonr incursion alert, & avoid it being logged as an incursion in the web portal, follow these steps:

  1. The Plant Operator and Machine Controller should be aware that someone wants to enter the exclusion zone and is prepared to approve the incursion.

  2. Option 1 - the Operator must press the menu button twice on the Base to reach the 'A' setting (approval mode), next, press and hold down the menu button on the Base for 3 seconds to start the approval mode (A). At this point, the A on the screen should start flashing, indicating it’s ready for the next step.

  3. Option 2 - the Machine Controller can activate Safe Mode from their MC Tag by pressing the yellow button.

  4. The Tag wearer should now press their button. The Tag will also make a triple beep, indicating that it has been approved to enter the exclusion zone.

  5. At this point, the screen on the Base should also show a tick. This confirms that the approval is successful.

This process can be repeated with multiple Tags to approve multiple entries into the exclusion zone. This process has to be done on a Tag by Tag basis; simultaneous approvals are not possible.

When an approved Tag enters the exclusion zone, a larger orange square will display on the Base, indicating that there is an approved incursion currently in progress.

Once the person with the Tag exits the exclusion zone for 60 secs or more, the exclusion zone for that Tag is reinstated.

Last updated